Catalog

Horizontal converters

Horizontal converters are designed for receipt of blister copper or nickel matte (or copper-nickel matte) by oxygen-enriched air blowing of melted semi-finished product. The converter may be manufactured of any production capacity within specified range.


Capacity, t Dimensions, mm
B C D E F G H
10 3120 1450 2300 2625 1460 2290 1410
40 5007 2700 3694 3040 1920 4850 3397
80 5550 4250 3950 3420 2150 5350 4725
100 5550 5100 3950 3940 2190 5350 4725
Capacity, t Dimensions, mm n
K L m P R
10 1672 8085 152 1460 2316 11
40 4712 12010 152 2520 3698 31
80 7752 14970 152 3000 5597 51
100 9272 17800 152 3780 6425 61

Engineering data name Rate
Converter production capacity per one cycle, t 10 40 80 100
Number of lance channels 12 32 52 62
Inside diameter of lance tube, mm 34 41 50 50
Throat area, m2 0,78 4,2 6,1 7,2
Converter rotation speed, rpm 1 0,7 0,7 0,7
Max.discharge capacity based on air, m3/min 97 600 800 1000
Operating electric motor power, kW 11 30 50 75

Delivery set includes:
• converter (without air blast and dust cap);
• electrical equipment on mechanisms;
• shields and control panels;
• spare parts;
• operation documents.